The Berridge Vee-Panel is a versatile, maintenance-free prefinished steel panel for soffit or wall and may be installed over open spans. Vee-Panel also may be applied vertically for facade, fascia or siding. Berridge Vee-Panel has a coverage of 10-7/8" (nominal 11" wide).
Vee-Panel Specifications
To use these specs in your project document, just use your mouse to drag and select all specification copy, then copy to the clipboard (CTRL - C), then paste into an open document (CTRL -V).
MANUFACTURER
Berridge Manufacturing Company
1720 Maury Street
Houston, Texas 77026
Phone: (800) 231-8127 Outside TX
(713) 223-4971 In TX
Fax: (713) 236-9422
PDF
DATA SHEET (4 MB FILE)
PDF
File of Installation Details
VEE-PANEL
The Berridge Vee Panel is a prefinished hidden fastener panel with nominal 10-7/8" coverage and vee-grooves. Vee-Panel is used for vertical walls, facades, fascia or other siding.
- Soffit, Wall & Facade Panel
- Open Framing or solid deck applications
- Hidden fasteners
- Vee-groove appearance
- Optional Vented Vee-Panel for Soffits
PART 1 GENERAL
1.01 SECTION INCLUDES
A. Preformed, prefinished metal roofing and flashings.
B. Miscellaneous trim, flashing, closures, drip flashing,
and accessories.
C. Fastening devices.
1.02 RELATED SECTIONS
A. Section 05120: Structural Steel Framing.
B. Section 05500: Miscellaneous metal fabrication.
C. Section 06100: Rough Carpentry.
1.03 REFERENCES
A. American Iron & Steel Institute (AISI) Specification for the Design of Coldformed Steel Structural Members.
B. ASTM A-653 & ASTM A924 Steel Sheet, Zinc-Coated (Galvanized)
C. Spec Data Sheet - Galvalume Sheet Metal by Bethlehem Corp.
D. SMACNA - Architectural Sheet Metal Manual.
1.04 ASSEMBLY DESCRIPTION
A. The assembly includes preformed sheet metal panels, related accessories, corners, miscellaneous flashing and attaching devices.
1.05 SUBMITTALS
A. Submit detailed drawings showing layout of panels, anchoring details, joint details, trim, flashing, and accessories
B. Submit a sample of each type of panel, complete with factory finish.
C. Submit calculations with registered engineer seal, verifying roof panel and attachment method resists windpressures imposed on it pursuant to applicable building codes.
1.06 QUALITY ASSURANCE
A. Manufacturer: Company specializing in ArchitecturalSheet Metal Products with ten (10) years minimum experience.
B. No product substitutions shall be permitted without meeting specifications.
C. Substitutions shall be submitted 10 Days prior to Bid Date and acceptance put forth in an addendum.
D. No substitutions shall be made after the Bid Date.
1.07 DELIVERY, STORAGE AND HANDLING
A. Upon receipt of panels and other materials, installershall examine the shipment for damage and completeness.
B. Panels should be stored in a clean, dry place. One end should be elevated to allow moisture to run off.
C. Panels with strippable film must not be stored in the open, exposed to the sun.
D. Stack all materials to prevent damage and to allow for adequate ventilation.
1.08 WARRANTY
A. Paint finish shall have a twenty year guarantee against cracking, peeling and fade (not to exceed 5 N.B.S. units).
B. Galvalume material shall have a twenty year guarantee against failure due to corrosion, rupture or perforation.
PART 2 PRODUCT
2.01 ACCEPTABLE MANUFACTURERS
A. Berridge Manufacturing Company, Houston, Texas.
B. Substitutions shall fully comply with specified require-ments.
2.02 SHEET MATERIALS
A. Prefinished Metal shall be Hot-Dipped Galvanized - ASTM A446-85 Grade C G90 Coating A525-86 24 Gauge core steel or prefinished Galvalume - ASTM 792-86 AZ-55.
B. Unfinished Metal shall be Grade C Galvalume ASTM 792-86, AZ 55, "Satin Finish".
C. Finish shall be [full strength Kynar 500 Fluoropolymer coating] [Copper-Cote][Lead-Cote] [Champagne] coating, applied by the manufacturer on a continuous coil coating line, with a top side dry film thickness of 0.70 to 0.90 mil over 0.25 to 0.35 mil prime coat, to provide a total dry film thickness of 0.95 to 1.25 mil. Bottom side shall be coated with primer with a dry film thickness of 0.25 mil. Finish shall conform to all tests for adhesion, flexibility, and longevity as specified by the Kynar 500 finish supplier.
D. Strippable film shall be applied to the top side of the painted coil to protect the finish during fabrication, shipping and field handling. This strippable film must be removed before installation.
2.03 ACCESSORY MATERIALS
A. Fasteners: [Galvanized Steel] [Stainless Steel] [Cadmium Plated Steel] with washers where required.
2.04 FABRICATION
A. All exposed adjacent flashing shall be of the same material and finish as the roof panels.
B. Hem all exposed edges of flashing on underside, 1/2 inch.
2.05 BERRIDGE VEE-PANEL
1. Panels shall have 10-7/8" exposure, 3/8" deep vee grooves at 3-5/8" on center, with concealed fasteners and interlocking sidelap.
2. Panels shall be site formed with the Berridge VEE-14 Portable Roll Former in continuous length per [wall][fascia] (or) [soffit] length or factory fabricated to 40' max.
3. Attachment to metal supports with #8 x 12" TEKS screws at maximum spacing of 2'-0" on center or per local code, whichever is greater.
4. Optional Vented Vee-Panel to have a Net Free Vent Area (NFVA) of 9.07 square inches per lineal foot of panel 10.01 square inches for square foot of panel
PART 3 EXECUTION
3.02 INSTALLATION
A. Comply with manufacturers standard instructions and conform to standards set forth in the Architectural Sheet Metal Manual published by SMACNA, in order to achieve a watertight installation.
B. Install panels in such a manner that horizontal lines are true and level and vertical lines are plumb.
C. Install starter and edge trim before installing roof panels.
D. Remove protective strippable film prior to installation of roof panels.
E. Attach panels using manufacturer's standard clips and fasteners, spaced in accordance with approved shop drawings.
F. Do not allow panels or trim to come into contact with dissimilar materials.
G. Protect installed panels and trim from damage caused by adjacent construction until completion of installation.
J. Remove and replace any panels or components which are damaged beyond successful repair.
3.03 CLEANING
A. Clean any grease, finger marks or stains from the panels per manufacturer's recommendations.
B. Remove all scrap and construction debris from the site.
3.04 FINAL INSPECTION
A. Final inspection will be performed by a firm appointed and paid for by the owner in accordance with section 01410.
END OF SECTION
NOTE: Please reference Berridge Manufacturing Company's current Sweet's Catalog 07610/BER , Sweet's BuyLine 49510 and 07410/BER for standard product offering with regard to materials, gauges, finishes and colors available.
Return to Factory Products page